Service and Repair for Mobility Scooters, Electric Wheelchairs, Recliner Lift Chairs. If you need to locate a repair shop / technician near you. How to check and solve the most common mobility scooter or power wheelchair problems: The most common problems with a power wheelchair or mobility scooter will be related to the batteries, charging, circuit breakers, keys / switches, cables, connectors or free wheel levers. Direct battery problems occur because they're, old and can no longer hold a good charge, not that old but have been pre-maturely worn down (due to any number of reasons), or just not being fully charged. IMPORTANT: Problems related to the batteries only, occur because the batteries are not fully charged, or it could be that the batteries are worn down and can not hold a proper charge. If the batteries are not holding a charge, and are old, you just need to have them replaced. If batteries are not that old, it may be that you have not been charging them properly (check the manual).
If the batteries are not worn down but your device does not get the range it did, it could be that the motors or other components are drawing too much current from the batteries. It can even be a wheel that is dragging which will discharge the batteries quickly. Here are some other non-direct battery problems to check. What can I do if my mobility scooter does not power up? Verify that the key is fully inserted into the key switch. Verify that the battery pack (some scooters may not have a battery pack) is seated properly. Verify that the battery quick-disconnect harness connections are fully joined.
Verify that the batteries are connected correctly, red to positive (+) and black to negative (-). Verify that the main circuit breaker has not been tripped. FYI: If your device is beeping and or flashing check the table below to help diagnose the problem (the chart is for the most common controllers, check your manual to verify). BATTERIES - Mobility Scooter and Power Wheelchair Charging and Testing: Q: How often should I charge? A: Daily Users: Charge daily.
This applies to anyone who actually uses his or her equipment outside of the home. Occasional Users: Always be sure to charge before an outing and always after active use. The ideal recharge point is about 50% on a scooter or wheelchair gauge.
Q: How do I charge my MK Batteries correctly? A: To properly charge your mobility battery, follow these simple procedures: - Use the manufacturer’s automatic charger for all routine charging. Never use an automotive or wet-type charger on gel/sealed batteries. (They’ll quickly ruin your battery). Never run your battery completely flat.
Don’t “top off” the battery with frequent charging. Q: How should a battery be stored?
A: - Always store your batteries FULLY CHARGED. Check all batteries once a month and recharge as needed. Wet batteries can hold their charge up to 3 months.
Sealed batteries can hold a charge for up to 6 months. When storing a chair or scooter for more than 2 weeks, charge the batteries and then disconnect them. Avoid hot and cold extremes when storing. Q: What is the proper way to store batteries for the Winter? A: Store batteries fully charged. Check them once a month and recharge as needed.
Sealed batteries can hold their charge from 6 to 12 months. Remember, if storing your chair for longer than a couple of weeks, it’s best to charge the batteries and then disconnect them. Q: I want to store my MK Gel batteries outside for the winter.
At what temperature do the batteries freeze at? A: MK Gel batteries can be stored in sub-freezing temperatures as low as -25°F without freezing as long as they are fully charged prior to storage. The self-discharge rate of fully-charged batteries is so low in these conditions that they will not require charging for many months; however, if your gel batteries are frozen they will not always recover.
To attempt recovery the following is the best plan of action: 1) Bring them inside and let them sit at room temperature for two days. (They must reach 60°F). 2) Charge the batteries normally. (Follow standard safety procedures).
3) Run a capacity check either through a quality discharge tester or by operating your power wheelchair in a controlled environment. 4) If you don’t get enough run time then repeat steps 2 and 3. Q: Do I have a battery problem or a charging problem? A: The Digital Voltmeter is still the most valuable tool in the Mobility Technician’s arsenal for sealed batteries.
The starting point for checking batteries is always the charge voltage. In 24-volt systems we know the chances for two bad batteries are less than 1 in 10,000. So what we need to determine is W HI CH battery is bad or if either battery is bad. This is accomplished by checking the voltage of each battery separately. As illustrated in photo 1, voltage for a pair of batteries can read in excess of 24-volts which can incorrectly be assumed to be a good set.
However, as shown in photo 2 one battery has a voltage of 12.89 volts while the battery in photo 3 is reading 11.97 volts. Combined, the voltage of this set of batteries looks good, but clearly the battery in photo 3 is bad. 3 Two batteries in a 24-volt system charge and discharge together almost as one 24-volt battery. A wide voltage separation between two batteries indicates that you may need to replace both batteries. If both batteries read similar voltage, they should be fully charged before doing any further testing.
If both batteries are below 12.0 volts, the question becomes, “WHY?” Is the battery charger working correctly? Could there be a problem with the wiring or other components of the wheelchair? You can determine the next step in the troubleshooting process once you know the voltage of each battery. Q: My batteries were over-discharged and my battery charger will not start. What do I do? A: Have you ever had a customer state that their batteries will not take a charge even though the charger was plugged in overnight? When you checked their batteries, you found that they both read 9 volts?
This is usually due to a light or a brake being left on for an extended period of time, which drains the batteries. The reason why the charger is not working is that most wheelchair battery chargers need to read at least 21-22 volts in order to begin charging. This is how the polarity protection system of many chargers works. If the user were to hook up the positive and negative backwards, nothing would happen to the charger or the batteries because the batteries never read any voltage so it never started.
The drawback to this polarity protection design is when a user over-discharges their batteries below the 21-22 volt cutoff. Although the charger is connected, it does not receive the signal to begin the charging process so the batteries never get charged. The best way to solve this problem is to remove the batteries from the wheelchair and charge each battery separately with a 12-volt battery charger. When each battery is fully charged, they can then be reinstalled in the chair and returned to service. Note: It may take the batteries up to 15 cycles to return to their former capacity if they have been severely discharged. Things to Consider When Purchasing Wheelchair/Scooter Batteries. Discharge: Gel Cell is preferred for wheelchair and / batteries because of its deep cycle life span.
The AGM battery will work nearly as well if the discharge rate is not below 50% before it is recharged. Range and Use: A battery's size determines its range.
By size, we mean the Amp Hours the battery is rated for. A 30 AH battery has a range of approximately 10 miles, while a 98AH battery has an approximate range of 20 miles. Range depends, of course, on how and where you use your wheelchair or mobility chair and what features it has.
If you need to locate a technician near you. Most power mobility equipment suppliers have technicians for repair and service in or near these cities: AL: Birmingham, Montgomery, Mobile, Huntsville. AZ: Phoenix, Tucson, Mesa, Glendale, Chandler, Scottsdale, Gilbert town, Tempe, Peoria. AR: Little Rock.
Each slide will send you through 425 feet of spiraling tubes until you reach the splash run finale. Prepare to drop down this 70-foot drop slide that let's you choose between two skyboxes. This water slide will literally pull the floor from under your feet. Are you brave enough to take on Vanish Point®? And smile for the camera, because we're capturing your moment live!
Pride Mobility, the manufacturer of Jazzy power chairs, is a widely recognized company known for its high performance mobility products. Owners of Jazzy power chairs should be aware that electromagnetic energy may cause interference with the control system of their wheelchairs. Do not use cell phones or citizens band (CB) radios while operating your wheelchair to avoid potential problems. Of course, not all problems related to Jazzy wheelchairs are related to electromagnetic interference (EMI). If you encounter a problem that you believe isn't related to EMI, you should charge the batteries of your power chair before you attempt to troubleshoot and repair your device.